High-quality products
Customized solutions
Personal contact
Fast service
Competent technical support +49(0)731-3608-123

One-Step RT-qPCR 2X Mastermix - Probe

Advantages at a glance

  • Ultra-Fast: RT-qPCR in <35 minutes
  • One-step RT-qPCR - One tube format
  • For probe-based assays such as Taqman®, Beacons, MGB or Mediator Probes
  • No need for Superscript!
  • Money saving: high!

Also available with ROX!

Just ask us!
info@genaxxon.com

€355.00*

Volume
Product number: SM3138.0200
Delivery time: 3- 8 working days
For detailed information on the delivery date, please contact Genaxxon.

Shipment: on wet ice. Store at -20°C. For laboratory usage only!
Product information "One-Step RT-qPCR 2X Mastermix - Probe"

Our One-Step RT-qPCR 2X master mix was developed for quantitative real-time analyzes of RNA templates using probe-based assays such as Taqman®, Beacons, MGB or Mediator Probes and can be directly used with RNA as a starting material. 

The ready-to-use mixture is based on a genetically modified reverse transcriptase with improved thermal stability, which offers increased specificity, a high cDNA yield and improved efficiency for highly structured and long cDNA fragments.

The 2X Mastermix contains all the reagents required for the RT-qPCR (except for the template, primer and probes) to ensure quick and easy handling at a minimum of pipetting steps. The high-quality enzymes and the optimized reaction buffer with high-purity dNTPs guarantee superior real-time PCR results. The sophisticated buffer system provides fast kinetics, a RNA sensitivity of <10 fg and target amplification even for difficult templates and multiplexing applications for more than 6 targets.

This Master Mix does not contain ROX - please make sure to choose the right setting on your qPCR cycler. A list of common thermal cyclers and their ROX compatibility can be found under the "Tips" tab.

RT-qPCR is used to amplify double-stranded DNA from single-stranded RNA templates to enable rapid real-time quantification of RNA targets. In the reverse transcription step, the reverse transcriptase synthesizes single-stranded DNA molecules (cDNA). The cDNA molecules are amplified by the HotStart DNA polymerase. The HotStart polymerase activity is blocked at ambient temperature and will be activated at the beginning of the initial denaturation. This thermal activation prevents the extension of non-specifically annealed primers and primer-dimer formations at low temperatures during the PCR setup.

One-Step RT-qPCR offers enormous convenience when analyzing targets from multiple RNA samples and minimizes the risk of contamination.

For RNA with a high degree of secondary structures or for complementary primers, the HotScriptase Master Mix (M3064) is particularly suitable. It enables the direct synthesis of double-stranded DNA without the time-consuming isothermal transcription step. Time savings: up to 50%. 

With our high-quality dNTPs, available as a set (M3015) or as a mix (M3016), as well as our DNA markers and affordable standard agarose, we offer you additional products for PCR.

Time saving: up to 50%! 
No need for Superscript!
Money saving: high!

Specifications:
Ready-to-use 2-time RT-qPCR mix
with Reverse Transcriptase
with Hot Start Polymerase
with RNase Inhibitor
with dNTPs
without ROX®


Applikation / Application:
reverse transcription qPCR

Einheiten / Units:
Quelle / Source:
synthetic


Sicherheits Hinweise / Safety


Klassifizierungen / Classification

eclass-Nr: 32-16-05-02
Documents - Protocols - Downloads :
Here you will find information and further literature. For further documents (certificates with additional lot numbers, safety data sheets in other languages, further product information) please contact Genaxxon biosience at: info@genaxxon.com or phone: +49 731 3608 123.


Documents:

Manuals
Category List
Listed below are articles and references, in which the authors trust in the high quality of this Genaxxon product.
Source: NCBI PubMed


Compatibility table for ROX usage in PCR cyclers

Supplier qPCR Cycler ROX?
Applied Biosystems /Thermo Fischer StepOne™ Real-Time PCR System Yes (high ROX)
StepOnePlus™ Real-Time PCR System Yes (high ROX)
7500 Real-Time PCR System Yes
7500 Fast Real-Time PCR System Yes
7500 Fast Dx Real-Time PCR Instrument Yes
7500 Real-Time PCR System for Human Identification Yes
7300 Real-Time PCR System Yes (high ROX)
Viia™ 7 Real-Time PCR System Yes
7900HT Fast Real-Time PCR System Yes (high ROX)
OpenArray® Real-Time PCR Platform Yes (high ROX)
PRISM® 7000 Sequencing Detection System Yes (high ROX)
PRISM® 7700 Sequencing Detection System Yes (high ROX)
PRISM® 7900 Sequencing Detection System Yes (high ROX)
Gene Amp 5700 Yes (high ROX)
Quantstudio™ 3 / 3 FAST Yes
Quantstudio™ 5 / 5 FAST Yes
Quantstudio™ 6 Yes
Quantstudio™ 7 Yes
Quantstudio™ 12 Yes
QuantStudio™ 12K Flex system Yes
Bioneer Exicycler™96 No (optional)
Exicycler™384 No (optional)
Biorad CFX96™ Real-Time PCR Detection System No
CFX96 Touch™ Real-Time PCR Detection System No
CFX384 Touch™ Real-Time PCR Detection System No
CFX Opus 96 Real-Time PCR System No
CFX Opus 384 Real-Time PCR System No
CFX Connect™ Real-Time PCR Detection System No
iQ5 Real-Time PCR Detection System No
MiniOpticon™ Real-Time PCR Detection System No
Opticon 2 – Continuous Fluorescence Detection System No
Chromo4™ Four-Color Real-Time Detector No
DNA Technology Dtlite No (optional)
Dtprime No (optional)
Eppendorf Mastercycler® ep realplex 4, Real-Time Thermal Cycler No
Mastercycler® ep realplex 4s, Real-Time Thermal Cycler No
Mastercycler® ep realplex, Real-Time Thermal Cycler No
Mastercycler® ep realplex s, Real-Time Thermal Cycler No
Mastercycler Nexus No
Mastercycler Nexus gradient No
Mastercycler Pro No
Mastercycler Pro S No
Mastercycler Pro 384 No
Roche LightCycler® 96 System No
LightCycler® 480 System No
LightCycler® 2.0 Instrument No
LightCycler® 1.5 Instrument No
LightCycler® 1536 System No
LightCycler® Nano System No
Analytik Jena qTower Yes
qTower 2.0 Yes
qTower 2.2 Yes
qTower 3 Yes
qTower 3 84 Yes
Stratagene / Agilent AriaMx Real-time PCR System No
Mx3000P® qPCR System Yes
Mx3005P® qPCR System Yes
Mx4000® qPCR System Yes
Qiagen Rotor-Gene™ Q Yes
Rotor-Gene™ 6000 Yes
Quantabio Q No (optional)

RT-PCR: Eine Geschichte der Entfaltung der Genregulation

Die Popularität der RT-PCR oder Reversen Transkriptions-PCR ist im Zuge der Coronavirus-Pandemie enorm gewachsen.

One step and Two step RT-PCR

We now have a faster RT-PCR version where both steps are combined into one.

RT-qPCR analysis of non-protein-coding RNA biomarker expression

RT-qPCR analysis of non-protein-coding RNA biomarker expression