LyoBalls lyophilized qPCR master mix - pre-dispensed



Order number: M3070.0196

Shipping: Shipment: not cooled. Store at +15°C to +30°C. For laboratory usage only!

Delivery time: 3- 8 working days
For detailed information on the delivery date, please contact Genaxxon.

€141.52 *

pack size:

Please select the favoured pack size.

While using our LyoBalls there is no need for cooling anymore! The balls and all ingredients are... more
Product information "LyoBalls lyophilized qPCR master mix - pre-dispensed"

While using our LyoBalls there is no need for cooling anymore! The balls and all ingredients are unopened stable at ambient temperature for at least 24 months! 

Lyophilized (freeze-dried) temperature stable, pre-mixed and pre-dispensed Hotstart master mix with all necessary components for probe realtime PCR (optimized buffer, dNTPs, Hotstart Taq) for difficult to amplify templates, qPCR and Multiplex applications. Only PCR-grade water has to be added to get the ready-to-use PCR master mix.

The lyophilized master mix is supplied in a "break-a-way" 96-well PCR plate. The plate can be divided into individual "8's strips". Thus, you have the variability to run smaller or larger preparations, depending on your needs.

No cooling/cooling chain necessary! The beads and all ingredients are unopened stable at ambient temperature for at least 24 months!

Our Hotstart Polymerase guarantees that during setup and the first PCR cycle the enzyme is not active and misprimed primers are not extended. As a result specificity and efficiency are increased by far compared to standard Taq DNA polymerase. Additionally, difficult targets with high GC-content can be amplified. The higher sensitivity improves multiplex PCR results.
This lyophilized master mix in a easy to handle bead format is the perfect choice for a fast reaction setup that reduces the time required for pipetting and the possibility for pipetting errors. Just add  PCR-grade water, template and primers to reconstitute the master mix and you are all set!

Lyophilized realtime PCR master mix:

•    Hotstart Polymerase
•    increased specificity
•    increased sensitivity
•    for difficult to amplify templates with high GC content
•    for Multiplex applications
•    for qPCR
•    ready-to-use
This lyophilized Hotstart master mix is delivered in single beads that can be easily dispensed. Each bead is equivalent to one 20µL PCR reaction.

Our lyophilized qPCR Probe master mix is available in powder form (LyoMix, M3071) > and pre-dispensed in a breakable 96-well PCR plate.

We also offer our SuperHot Hotstart Master Mix > with and without dye.

With our high quality dNTPs as Set (M3015.4100 and M3015.0250) > or Mix (M3016.1010) > or our DNA Ladders > and our favourable standard agarose (M3044) > we can offer additional products for your PCR.

More products around "LyoBalls lyophilized qPCR master mix - pre-dispensed"
Our comment on "LyoBalls lyophilized qPCR master mix - pre-dispensed"
- pre-dispensed, freeze-dried realtime PCR reagents mix in bead format. - only add template DNA solution and primers, and cycle. - less risk of pipetting errors and contamination thus more reliable and reproducible. - long-term ambient-temperature stable
Specifications: LyoBalls are a ready-to-use freeze-dried master mix that contains all... more
 

Technical Data:

Specifications:
LyoBalls are a ready-to-use freeze-dried master mix that contains all necessary components for realtime PCR.
Aliquot size: 1 bead = 1 PCR reaction.
Standard pack format: predispensed in a breakable PCR plate (0.2mL wells). Plate easily breakable in strips of 8 wells. Wells closed with 8 cap strips.

This master mix is stable for at least 24 months at ambient temperature if the supplied plate is kept unopened!

application:

For multiplex PCR. For Real-time PCR. For PCR of low amount of DNA (low copy number).

Unit Definition:

One unit is defined as the amount of enzyme which will convert 10 nmoles of dNTPs to an acid-insoluble form in 30 min at 72°C under the assay conditions (25 mM TAPS (tris-(hydroxymethyl)-methyl-amino-propanesulfonic acid, sodium salt) pH 9.3 (25°C); 50 mM KCl; 2 mM MgCl2; 1 mM b-mercaptoethanol; and activated calf thymus DNA as substrate.

Source

recombinant

Sicherheits Hinweise / Safety

Klassifizierungen / Classification

eclass-Nr: 32-16-05-02
Dokumente - Protokolle - Downloads more


Dokumente - Protokolle - Downloads

Here you will find information and further literature on LyoBalls lyophilized qPCR master mix - pre-dispensed. For further documents (certificates with additional lot numbers, safety data sheets in other languages, further product information) please contact Genaxxon biosience at: info@genaxxon.com or phone: +49 731 3608 123.

 
 
 
Dokumente - Protokolle - Downloads more

Dokumente - Protokolle - Downloads

- LyoBalls can look wet. This is due to a specially developed active ingredient that protects the balls from absorbing moisture but does not interfere with the PCR reaction.

- LyoBalls dissolve within seconds at room temperature without further mixing.

- Master mixes, whether liquid or lyophilized, from different companies contain different components, which most likely leads to different annealing and melting behaviour of DNA, primers and probes in your PCR! It is most likely not possible to perform the same PCR protocol with the LyoBalls that has already been defined for another master mix.

- If you use LyoBalls for the first time or create a new primer set, perform a PCR with a temperature gradient in the annealing and extension step to determine the optimal temperature for your assay or each primer pair.

- The annealing temperature of a primer is strongly influenced by its nucleic acid sequence AND the reaction composition (pH, salts and salt concentration of the reaction buffer used). It has been shown that the annealing temperature with Genaxxon's LyoBalls is probably about 2-3°C lower compared to the original systems!

 
 
 
FAQ
Fragen & Antworten zum Artikel ... mehr
Why do I need a Hot Start Polymerase for a qPCR?
The Hot Start-modification of the polymerase inhibits its enzymatic activity at low temperatures and prevents non-specific amplifications in the first PCR cycles, which can drastically affect the qPCR results.
What is the Ct or Cq value?
The Ct (Threshold Cycle) value in qPCR is a measure of gene expression and is determined based on the fluorescence curve. The 2nd derivative method is used to determine the maximum change in the second derivative of the fluorescence curve - i.e. the point at which the fluorescence change no longer increases - and thus the exponential amplification is terminated. The cycle in which this is the case is called the "quantification cycle (Cq)". Please note that the calculation of the Cq value can also be done by other methods. It is important that you always use the same method for your experiment.
What is ROX?
ROX (5-Carboxy-Rhodamin-X) is a fluorescent dye that some qPCR machines use as a passive reference dye. This is done to account for fluorescence variations between wells, which can result from factors like material inconsistencies or imprecise pipetting. In general, it's advisable to take advantage of this normalization option whenever possible. It's essential to determine whether your system requires a low (low ROX) or high (high ROX) concentration of ROX. However, if your cycler lacks a ROX option, there's no need to be concerned. A well-optimized qPCR typically doesn't require additional normalization through a passive dye. Genaxxon provides qPCR master mixes with ROX concentrations that range from none to low or high, catering to all your needs.
How can I calculate primer efficiency?
It's essential to determine primer efficiency for every gene you're analyzing. To do this, create a cDNA dilution series covering a range of 5-6 orders of magnitude and record Cq values for different primer concentrations. You can calculate the primer efficiency from the slope of the resulting line, aiming for it to be within the range of 85% to 110%.
Do qPCR plates and foils influence the assay performance?
Yes, the used plates and foils could influence the assay performance according to several scientific studies (e.g. Reiter and Pfaffl 2008: Effects of Plate Position, Plate Type and Sealing Systems on Real-Time PCR Results, Biotechnology & Biotechnological Equipment, 22:3, 824-828, DOI: 10.1080/13102818.2008.10817561). In general, white qPCR plates (e.g. Genaxxon’s I2017) have a lower light scattering and thus a higher signal strength than transparent qPCR plates (e.g. Genaxxon’s I2004, I2010, I2031). If you have a weakly expressed target or a only small amounts of sample material, we recommend using a white qPCR plate. Beside this, it is essential to use optically clear foils for your qPCR. We do not recommend using “normal” PCR foils as adhesive residues and transparency differences in the material may lead to inhomogeneity during your qPCR assay. Genaxxon offers different qPCR foils: a strongly adhesive foil (I2012) that securely seal the plate immediately, and a pressure-sensitive foil (I2248) that adheres to the plate by applying strong pressure.
What are TaqMan Probes?
TaqMan® probes are hydrolysis probes used in qPCR for measuring DNA levels. Hydrolysis probes are single-stranded DNA oligonucleotides labeled with a fluorescent marker at one end and a quencher at the other. The quencher is a molecule that suppresses the fluorescence of the marker when they are in close proximity. When the probe binds to the DNA target and the polymerase initiates amplification, its exonuclease activity cleaves both the fluorescent marker and the quencher. This action removes the quencher's inhibitory effect. Since this process repeats in every cycle, the strength of the fluorescence signal, measured after excitation, is directly proportional to the amount of amplified DNA.
When should I use TaqMan probes, and when should I opt for SYBRGreen?
Hydrolysis probes (TaqMan) excel in applications such as SNP genotyping, splice variant analysis, and mutation detection using qPCR. In contrast, SYBRGreen-based assays are ideal for gene expression or miRNA expression analysis and offer additional advantages, including quality metrics like melting curve analysis. Several scientific studies suggest that a properly optimized SYBRGreen assay is as effective as a hydrolysis probe (TaqMan) for gene expression analysis (e.g., Tajadini et. al. 2014: Comparison of SYBR Green and TaqMan® methods in quantitative real-time polymerase chain reaction analysis of four adenosine receptor subtypes, Advanced Biomedical Research, 3, 85, DOI: 10.4103/2277-9175.127998). Key factors for success in both cases include selecting appropriate primers, optimizing the qPCR master mix, and ensuring high-quality, non-fragmented cDNA, which is crucial for TaqMan® probes as well. Please not that the performance of a qPCR assay utilizing (TaqMan) probes is heavily influenced by the amplicon length, affecting its robustness, sensitivity, and specificity. In contrast, an assay with SYBRGreen demonstrates greater tolerance for variations in amplicon lengths.
How can I check the specificity of my qPCR assay?
To confirm specificity, you can perform post-qPCR analysis by either running the reaction mix on an agarose gel or, if you're using SYBRGreen, generating a melting curve. These methods will quickly indicate the presence of any unintended byproducts.
What controls are essential in qPCR?
Just like any experiment, it's crucial to include the right controls in every qPCR assay. Depending on the assay format, we recommend the following controls: 1. No Template Control (NTC): For every gene being analyzed, it's important to incorporate an NTC (simply using water instead of a template). NTCs play a critical role in detecting cross-contamination and should be a standard part of every qPCR. 2. Reference Genes (formerly known as Housekeeping Genes): To ensure a robust gene expression analysis, it's a good practice to include multiple reference genes for each sample. These reference genes should exhibit stable expression regardless of any treatment, serving as reference points for subsequent relative quantification. 3. Alternative Positive Control: In cases where you're performing absolute quantifications and not using reference genes, including an alternative positive control is recommended. This control should consistently yield a known result in all scenarios. 4. noRT Control: If you're using reverse transcription (RT) from mRNA as the template, it's advisable to have a noRT control with a sample that lacks the enzyme.
Do I need to do a melting curve analysis?
Please note that a melting curve analysis is only possible when doing a qPCR with intercalating dyes, e.g. SYBRGreen, but not with probes. The melting curve can be used to determine the specificity of a qPCR and to detect any by-products that may occur. It is therefore strongly recommended to perform a melting curve analysis for every qPCR when using an intercalating dye. To generate the melting curve, the qPCR cycler continuously increases the temperature and simultaneously measures the fluorescence. This drops as soon as the melting temperature of the amplicon produced during qPCR is exceeded. Why? When the product melts, the intercalating dye is released, causing the fluorescence signal to drop. Usually, the melting curve is not shown directly as a fluorescence curve, but as a function of the change in fluorescence. A large change in fluorescence is represented as a peak (amplicons denature in this area). Please note that a qPCR always shows only a single peak. Multiple peaks are - with the exception of multiplex assays! - a clear indication of unwanted by-products. These can, under certain circumstances, completely falsify the result and make it unusable. Please note: When changing your master mix, the peak of a melting curve may shift. Why? The melting temperature also depends on the buffer used in the master mix, especially on the salt concentration. As different master mixes may use different buffer, it is quite likely that the resulting melting curve differs.
What is the optimal primer concentration?
The concentration of primers plays a crucial role in qPCR performance and should be carefully optimized. Having a primer concentration that is too high or too low can negatively impact the calculation of the Cq value and may even encourage the formation of primer dimers (see e.g., Mikeska and Dobrovic 2009: Validation of a primer optimisation matrix to improve the performance of reverse transcription – quantitative real-time PCR assays, BMC Research Notes, 2, 112, DOI: 10.1186/1756-0500-2-112). As a general guideline, you can initiate with a primer concentration of 100-200 nM. However, it's important to conduct test assays with both higher and lower concentrations to identify the optimal range.
How can I calculate primer efficiency?
It's essential to determine primer efficiency for every gene you're analyzing. To do this, create a cDNA dilution series covering a range of 5-6 orders of magnitude and record Cq values for different primer concentrations. You can calculate the primer efficiency from the slope of the resulting line, aiming for it to be within the range of 85% to 110%.
How much template do I need for my qPCR?
The precise amount of template required for a specific qPCR is contingent on various factors. Excessive template can potentially inhibit the qPCR. In a typical qPCR, the range for template usage per reaction falls between 1 and 10 ng. Therefore, when initiating qPCR optimization, it's highly recommended to establish a template dilution series covering 5 to 6 orders of magnitude. This step is vital for determining the optimal template quantity. This dilution series assists in determining the primer efficiency, the potential for qPCR inhibition by the template, and the verification of whether the template quantity falls within the qPCR's linear range. Once these parameters are established, you can confidently select a template quantity that aligns with the linear range of the qPCR.
My qPCR assay is not as specific as it should be. What can I do?
The specificity of a qPCR assay depends on several factors, including primer concentration, the melting temperature of the primers, annealing temperature and time, and the potential formation of primer dimers. If your qPCR assay lacks the desired specificity, we recommend the following: 1. Reduce the primer concentration. 2. Increase the annealing temperature (while ensuring it doesn't exceed the melting temperature of the primers). 3. Shorten the annealing time. If none of these measures prove effective, consider redesigning the primers, exploring various options for length, melting temperature, and sequence.
When using SybrGreen as a fluorescent dye, my quantification is not accurate. What can I do?
SybrGreen has only a low specificity. It binds to double-stranded DNA during PCR cycles, even to potentially non-specific reaction products. This leads to inaccurate qPCR results with non-optimised protocols. To obtain more specific results, probe-based qPCR should be performed.
With the qPCR master mix from Genaxxon I get a different Ct value than with my previous master mix. What can I do?
The master mixes from different manufacturers have different compositions, including the buffers. Some assays react sensitively to these variations, so that different results are possible. Therefore, a calibration is always necessary when changing the master mix. If you have further questions, please contact our technical support: info@genaxxon.com.
The qPCR master mix does not work with the specified protocol. What can I do?
The protocols provided by Genaxxon are standard protocols. In order to obtain optimal specificity and amplification, individual optimisation of the experimental conditions is recommended. If you have further questions about this, please feel free to contact our technical support: info@genaxxon.com.
Do I need to add ROX when using Genaxxon’s qPCR master mixes?
Depending on the qPCR instrument you’re using, you may need to use a passive reference dye, typically ROX, to overcome variations between wells caused by the machine limitations. Therefore, Genaxxon offers qPCR master mixes with either no or low and high amounts of the passive reference dye RO to ensure compatibility with a variety of qPCR instruments. If you have any problems choosing the right master mix for your application, please contact our technical support: info@genaxxon.com.
Can I use a fast protocol of my instrument settings with Genaxxon’s qPCR master mixes?
Genaxxon offers different qPCR master mixes optimised for fast qPCR assays. Depending on your needs, Genaxxon offers master mixes for fast qPCR assays with (GreenMasterMix FAST) or without (ProbeMasterMix FAST) a fluorescence dye and with no (No ROX) or a passive reference dye with different concentrations (Low ROX or High ROX). If you have any problems choosing the right master mix for your application, please contact our technical support: info@genaxxon.com.
Can I easily switch to another qPCR master mix during my project?
Yes, you can switch to another qPCR master mix during your project or even in the middle of your experiment! You only need to perform a normalization of your qPCR beforehand. Please note that we generally recommend normalization for any qPCR. Also, check if you need to adjust the settings on your PCR cycler when changing the master mix.
Can I run multiplex reactions with the Genaxxon qPCR master mixes?
Yes, all qPCR master mixes from Genaxxon can be used for multiplex applications. However, for easy and fast optimization of your multiplex reaction, we recommend using one of our specially designed multiplex master mixes, e.g., 5X qPCR Multiplex MasterMix (M3024), Multiplex HS MasterMix (2X) (M3013) or the lyophilized LyoPlex Multiplex PCR master mix (M3005).